Snap-Action Power Switches
Construction Details
Shallco snap-action switches comprise assemblies of electrically insulated stators and rotors as an integral assembly with a drive mechanism that indexes the rotors in 90 degree increments. The unique drive mechanisms employ stored energy that, when released, provides millisecond "open" and/or "closure" of electrical circuits.
The stationary stator contacts may be "non-shorting", "shorting" or "sweep" depending on appication requirements. The rotor designs allow for 180 degree (straight-across), 90 dgree (right-angle) and multi-blade types for up to four-throw switching.
Stators are premium electrical grade thermoset plastic and stationary contacts are heavy guage copper. The clip-style rotor blades are phospor-bronze riveted to a brass driving washer.
Features
- Positions: 2 to 4, up to 12 poles
- Double wiping contacts, low contact resistance
- Current ratings to 200 amperes
- Rapid make and break action
- AC and DC switching
- Many circuit variations available
Snap Action Catalog PDFs
Series 1 Switches PDF
Series 3 Switches PDF
Series 7 Switches PDF
Circuit Diagrams: Series 1 and Series 3 Snap-Action Switches
Circuit A, single throw
|
 |
| Poles |
Circuit Code |
| 1 |
|
| 2 |
|
| 3 |
|
| 4 |
|
|
|
Circuit B, double throw
|
 |
| Poles |
Circuit Code |
| 1 |
|
| 2 |
|
| 3 |
|
| 4 |
|
|
Circuit C, double throw
|
 |
| Poles |
Circuit Code |
| 1 |
|
| 2 |
|
| 3 |
|
| 4 |
|
|
|
Circuit D, double throw
|
 |
| Poles |
Circuit Code |
| 1 |
|
| 2 |
|
| 3 |
|
| 4 |
|
|
Circuit E, triple throw
|
 |
| Poles |
Circuit Code |
| 1 |
|
| 2 |
|
| 3 |
|
| 4 |
|
|
|
Circuit F, four throw
|
 |
| Poles |
Circuit Code |
| 1 |
|
| 2 |
|
| 3 |
|
| 4 |
|
|
Part Number Code
The above tables describe the six basic circuits available for the Shallco Series 1 (10 ampere) and Series 3 (30 ampere) snap-action rotary switches. A complete part number consists of the circuit code prefixed by the "series-number"; "1" for a 10 ampere device and "3" a the 30 ampere device, as in the following example.
3B02-4; 30 ampere, circuit "B", two pole, 4 position.
Outline Dimensions
| Series |
A |
B |
C |
D |
E |
F |
G |
H |
J |
| 1 |
1.64 |
10-24 |
.250 |
.766 |
.250 |
- |
1.50 |
8-32 |
2.50 |
| 3 |
2.281 |
1/4-20 |
.375 |
.937 |
.250 |
- |
2.75 |
10-24 |
4.13 |
|