Additional Circuit Diagrams
In addition to the standard circuits A, B, and C shown in the single-hole mount diagrams, we offer circuits D and E below. Circuits are shown here with the pointer knob in the 12 o'clock position.
Circuit D:
One pole per section, double-break switching
| Positions |
Contact Closures |
| 1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
(as viewed from shaft end) |
| X |
|
|
|
|
|
|
|
between 11 and 12 |
|
X |
|
|
|
|
|
|
between 12 and 13 |
|
|
X |
|
|
|
|
|
between 13 and 14 |
|
|
|
X |
|
|
|
|
between 14 and 15 |
|
|
|
|
X |
|
|
|
between 15 and 16 |
|
|
|
|
|
X |
|
|
between 16 and 17 |
|
|
|
|
|
|
X |
|
between 17 and 18 |
|
|
|
|
|
|
|
X |
between 18 and 11 |
Circuit E:
Progressively opening, MBB only. One circuit open, all other circuits closed and common to terminal No. 11
| Positions |
Contact Openings |
| 1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
(as viewed from shaft end) |
| X |
|
X |
X |
X |
X |
X |
X |
between 11 and 12 |
| X |
X |
|
X |
X |
X |
X |
X |
between 11 and 13 |
| X |
X |
X |
|
X |
X |
X |
X |
between 11 and 14 |
| X |
X |
X |
X |
|
X |
X |
X |
between 11 and 15 |
| X |
X |
X |
X |
X |
|
X |
X |
between 11 and 16 |
| X |
X |
X |
X |
X |
X |
|
X |
between 11 and 17 |
| X |
X |
X |
X |
X |
X |
X |
|
between 11 and 18 |
Series 16 Products
Series 16 Rotary Switch, 10 Ampere, Single-Hole Mount
Series 16 Rotary Switch,
Spring Return, Single-Hole Mount
Series 16 Key Operated Switches
|